Home > Motorized Linear Servo Stages

Linear Voice Coil Stage, VCDS-051-165-01-13
Continuous Force: 4.8 lb (21.5 N), Range of Motion: 5.20” (132.1 mm),  Resolution: 13 microns


 

Previous Buy Online View Cart Next
Voice Coil Driven Stage VCDS-051-165-01-13
 

Voice Coil Driven Stage with Quadrature Position Sensor and Home Switch

  • Range of Motion: 5.20” (132.1 mm) 
  • Positioning Resolution: 12.7 microns
  • Continuous Force: 4.8 lb (21.5 N)
  • Intermittent Force: 15.3 lbs (68.1 N) at 10% duty cycle
  • Optional Return Spring
  • Linear Ball Bearing
  • Quadrature Optical Encoder with Differential Outputs
  • Built-in Home Switch
VCDS-051-165-01-13
Datasheet in PDF Datasheet in PDF
Drawing quick view
Mechanical Drawing
 

STAGE SPECIFICATIONS

Intermittent Force @ 10% Duty Cycle

68.1 N

15.3

lb
Continuous Force 21.5 N

4.8

lb

Force Constant

10.6 N/A

2.4

lb/A
BACK EMF Constant 10.6 V/M/S

0.27

V/in/S

Stroke

133.4 mm

5.25

in
Moving Mass 955 gr

33.7

oz

Total Mass

6.4 kg

14

lb

Coil Resistance

12.2 Ohm

Coil Inductance at 1000 Hz

6.8 mH

Continuous Power

50 W

Connection

9 pin DB-9 Male Connector

Pin Assignment and Description


PIN

DESCRIPTION

1

+5 VDC Power (Quadrature Optical Encoder)

2

Return for +5 VDC Power (Home Switch)

3

Channel-A of Quadrature Optical Encoder

4

Channel-B of Quadrature Optical Encoder

5

Return for +5 VDC Power (Quadrature Optical Encoder)

6

Home Signal, Active High

7

+5 VDC Power (Home Switch)

8

Motor Minus

9

Motor Plus

 

Applying a positive voltage to pin-9 relative to pin-8 will move the motor outward.