Linear Voice Coil Motors
|
|
Linear
DC Motors, Voice Coil Motors (VCM) or Voice Coil Actuators (VCA) are the
simplest type of electric motors. These motors consist of two separate
parts; the magnetic housing and the coil.
Applying a
voltage across the terminals of the motor causes the motor to move to one
direction. Reversing the polarity of the applied voltage will move the motor to
the opposite direction. The generated force is proportional to the current that
flows through the motor coil. This force is almost constant in the specified
stroke range of the motor.
Voice coil motors are brushless and do not utilize commutation. Their structural stability can support high positioning resolutions presented by external position sensors and motion controllers.
The
non-commutated motor construction increases reliability. The direct coupling of
the motor to the load allows for fast acceleration / deceleration and high speed
operation.
Very high speeds
and accelerations can be easily achieved.
The moving part
needs to be supported by a mechanism supplied by the customer.
This type of
motor may be used in conjunction with a position sensor and a motion controller
for accurate positioning.
The other
applications of the voice coil motors are force and pressure control.
All the following
motors can be manufactured with metric threads in production quantities.
Mounting hardware
is available in various lengths and styles and may be obtained at
Linear DC Motors Catalog in PDF
Comparison table
Housing Outside Diameter: 0.375
inch, 9.5 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-010-013-01 |
0.25 |
inch |
1.0 |
oz |
3.2 |
oz |
0.500 |
inch |
|
6.4 |
mm |
0.28 |
N |
0.88 |
N |
12.7 |
mm |
Comparison table
Housing Outside Diameter: 0.500
inch, 12.7 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-013-008-02 |
0.125 |
inch |
2.9 |
oz |
9.1 |
oz |
0.313 |
inch |
|
3.2 |
mm |
0.80 |
N |
2.53 |
N |
8.0 |
mm |
Comparison table
Housing Outside Diameter: 0.500
inch, 12.7 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-013-013-02 |
0.25 |
inch |
3.1 |
oz |
9.8 |
oz |
0.500 |
inch |
|
6.4 |
mm |
0.86 |
N |
2.73 |
N |
12.7 |
mm |
Comparison table
Housing Outside Diameter: 0.500
inch, 12.7 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-013-019-02 |
0.50 |
inch |
2.9 |
oz |
9.2 |
oz |
0.750 |
inch |
|
12.7 |
mm |
0.81 |
N |
2.55 |
N |
19.1 |
mm |
Comparison table
Housing Outside Diameter: 0.500 inch, 12.7 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-013-025-02 |
0.75 |
inch |
2.9 |
oz |
9.0 |
oz |
1.000 |
inch |
|
19.1 |
mm |
0.79 |
N |
2.51
|
N |
25.4 |
mm |
Comparison table
Housing Outside Diameter: 0.500
inch, 12.7 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-013-032-02 |
1.00 |
inch |
2.5 |
oz |
7.9 |
oz |
1.250 |
inch |
|
25.4 |
mm |
0.70 |
N |
2.20 |
N |
31.8 |
mm |
Comparison table
Housing Outside Diameter: 0.500
inch, 12.7 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-013-044-02 |
1.50 |
inch |
2.5 |
oz |
8.0 |
oz |
1.750 |
inch |
|
38.1 |
mm |
0.71 |
N |
2.23 |
N |
44.5 |
mm |
Comparison table
Housing Outside Diameter: 0.500
inch, 12.7 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-013-044-03 |
0.60 |
inch |
6.9 |
oz |
21.7 |
oz |
1.750 |
inch |
|
15.2 |
mm |
1.9 |
N |
6.0 |
N |
44.5 |
mm |
Comparison table
Housing Outside Diameter: 0.625
inch, 15.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-016-010-01 |
0.125 |
inch |
5.9 |
oz |
18.6 |
oz |
0.375 |
inch |
|
3.2 |
mm |
1.6 |
N |
5.2 |
N |
9.5 |
mm |
Comparison table
Housing Outside Diameter: 0.625 inch, 15.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-016-013-01 |
0.25 |
inch |
6.3 |
oz |
20.0 |
oz |
0.500 |
inch |
|
6.4 |
mm |
1.8 |
N |
5.6 |
N |
12.7 |
mm |
Comparison table
Housing Outside Diameter: 0.625
inch, 15.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-016-019-01 |
0.50 |
inch |
6.1 |
oz |
19.3 |
oz |
0.750 |
inch |
|
12.7 |
mm |
1.7 |
N |
5.4 |
N |
19.1 |
mm |
Comparison table
Housing Outside Diameter: 0.750
inch, 19.1 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-019-016-02 |
0.25 |
inch |
8.9 |
oz |
28.0 |
oz |
0.625 |
inch |
|
6.4 |
mm |
2.5 |
N |
7.8 |
N |
15.9 |
mm |
Comparison table
Housing Outside Diameter: 0.750
inch, 19.1 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-019-022-02 |
0.5 |
inch |
8.1 |
oz |
25.7 |
oz |
0.875 |
inch |
|
12.7 |
mm |
2.3 |
N |
7.1 |
N |
22.2 |
mm |
Comparison table
Housing Outside Diameter: 0.750
inch, 19.1 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-019-032-02 |
0.875 |
inch |
8.1 |
oz |
25.7 |
oz |
1.250 |
inch |
|
22.2 |
mm |
2.3 |
N |
7.2 |
N |
31.8 |
mm |
Comparison table
Housing Outside Diameter: 0.750
inch, 19.1 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-019-048-02 |
1.5 |
inch |
7.4 |
oz |
23.5 |
oz |
1.875 |
inch |
|
38.1 |
mm |
2.1 |
N |
6.5 |
N |
47.6 |
mm |
Comparison table
Housing Outside Diameter: 0.875 inch, 22.2 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-022-013-01 |
0.25 |
inch |
14.5 |
oz |
45.7 |
oz |
0.500 |
inch |
|
6.4 |
mm |
4.0 |
N |
12.7 |
N |
12.7 |
mm |
Comparison table
Housing Outside Diameter: 0.875 inch, 22.2 mm - Large Radial Clearance Gap |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-022-013-02 |
0.25 |
inch |
5.9 |
oz |
18.7 |
oz |
0.500 |
inch |
|
6.4 |
mm |
1.6 |
N |
5.2 |
N |
12.7 |
mm |
Comparison table
Housing Outside Diameter: 1.000
inch, 25.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-025-022-01 |
0.38 |
inch |
16.9 |
oz |
53.5 |
oz |
0.875 |
inch |
|
9.5 |
mm |
4.7 |
N |
14.9 |
N |
22.2 |
mm |
Comparison table
Housing Outside Diameter: 1.000
inch, 25.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-025-022-02 |
0.19 |
inch |
26.5 |
oz |
83.9 |
oz |
0.875 |
inch |
|
4.8 |
mm |
7.4 |
N |
23.3 |
N |
22.2 |
mm |
Comparison table
Housing Outside Diameter: 1.000
inch, 25.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-025-029-01 |
0.63 |
inch |
18.2 |
oz |
57.7 |
oz |
1.125 |
inch |
|
15.9 |
mm |
5.1 |
N |
16.0 |
N |
28.6 |
mm |
Comparison table
Housing Outside Diameter: 1.000
inch, 25.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-025-029-02 |
0.31 |
inch |
37.6 |
oz |
118.9 |
oz |
1.125 |
inch |
|
7.9 |
mm |
10.5 |
N |
33.1 |
N |
28.6 |
mm |
Comparison table
Housing Outside Diameter: 1.000
inch, 25.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-025-038-01 |
0.37 |
inch |
2.5 |
lb |
7.8 |
lb |
1.50 |
inch |
|
9.5 |
mm |
11 |
N |
34.7 |
N |
38.1 |
mm |
Comparison table
Housing Outside Diameter: 1.000
inch, 25.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-025-038-02 |
1.00 |
inch |
16.4 |
oz |
51.9 |
oz |
1.50 |
inch |
|
25.4 |
mm |
4.6 |
N |
14.4 |
N |
38.1 |
mm |
Comparison table
Housing Outside Diameter: 1.250
inch, 31.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-032-025-02 |
0.50 |
inch |
2.1 |
lb |
6.6 |
lb |
1.00 |
inch |
|
12.7 |
mm |
9.3 |
N |
29.3 |
N |
25.4 |
mm |
Comparison table
Housing Outside Diameter: 1.250
inch, 31.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-032-038-02 |
1.00 |
inch |
1.9 |
lb |
5.9 |
lb |
1.50 |
inch |
|
25.4 |
mm |
8.3 |
N |
26.1 |
N |
28.6 |
mm |
Comparison table
Housing Outside Diameter: 1.250
inch, 31.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-032-076-02 |
2.50 |
inch |
1.8 |
lb |
5.7 |
lb |
3.0 |
inch |
|
63.5 |
mm |
8.0 |
N |
25.3 |
N |
76.2 |
mm |
Comparison table
Housing Outside Diameter: 1.500
inch, 38.1 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-038-038-01 |
0.75 |
inch |
3.0 |
lb |
9.5 |
lb |
1.50 |
inch |
|
19.1 |
mm |
13.4 |
N |
42.5 |
N |
38.1 |
mm |
Comparison table
Housing Outside Diameter: 1.500
inch, 38.1 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-038-038-02 |
0.38 |
inch |
5.6 |
lb |
17.7 |
lb |
1.50 |
inch |
|
9.5 |
mm |
24.9 |
N |
78.8 |
N |
38.1 |
mm |
Comparison table
Housing Outside Diameter: 1.750
inch, 44.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-044-032-02 |
0.50 |
inch |
5.0 |
lb |
15.8 |
lb |
1.25 |
inch |
|
12.7 |
mm |
22.2 |
N |
70.4 |
N |
31.8 |
mm |
Comparison table
Housing Outside Diameter: 1.750
inch, 44.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-044-051-01 |
1.25 |
inch |
4.9 |
lb |
15.4 |
lb |
2.00 |
inch |
|
31.8 |
mm |
21.6 |
N |
68.4 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 1.750
inch, 44.4 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-044-051-02 |
1.25 |
inch |
5.0 |
lb |
15.8 |
lb |
2.00 |
inch |
|
31.8 |
mm |
22.3 |
N |
70.4 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-025-01 |
0.50 |
inch |
5.3 |
lb |
16.9 |
lb |
1.00 |
inch |
|
12.7 |
mm |
23.7 |
N |
74.8 |
N |
25.4 |
mm |
Comparison table
Housing Outside Diameter: 2.000 inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-032-01 |
0.75 |
inch |
6.3 |
lb |
20.0 |
lb |
1.25 |
inch |
|
19.1 |
mm |
28.2 |
N |
89.9 |
N |
31.8 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-051-01 |
0.75 |
inch |
6.3 |
lb |
19.9 |
lb |
2.00 |
inch |
|
19.1 |
mm |
28.0 |
N |
88.6 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-051-05 |
1.00 |
inch |
6.6 |
lb |
20.8 |
lb |
2.00 |
inch |
|
25.4 |
mm |
29.3 |
N |
92.6 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm - Large Radial Clearance Gap |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-051-06 |
1.25 |
inch |
3.0 |
lb |
9.5 |
lb |
2.00 |
inch |
|
31.8 |
mm |
13.3 |
N |
42.2 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm - Large Radial Clearance Gap |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-051-07 |
0.625 |
inch |
5.02 |
lb |
15.9 |
lb |
2.00 |
inch |
|
15.9 |
mm |
22.3 |
N |
70.6 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-064-01 |
1.25 |
inch |
6.6 |
lb |
20.9 |
lb |
2.50 |
inch |
|
31.8 |
mm |
29.4 |
N |
92.9 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-064-02 |
0.50 |
inch |
15.3 |
lb |
48.5 |
lb |
2.50 |
inch |
|
12.7 |
mm |
68.2 |
N |
215.5 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-064-03 |
0.50 |
inch |
19.3 |
lb |
60.8 |
lb |
2.50 |
inch |
|
12.7 |
mm |
85.4 |
N |
270.0 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-064-05 |
2.00 |
inch |
5.8 |
lb |
18.4 |
lb |
2.50 |
inch |
|
50.8 |
mm |
25.8 |
N |
81.7 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-089-01 |
2.25 |
inch |
5.9 |
lb |
18.6 |
lb |
3.50 |
inch |
|
57.2 |
mm |
26.2 |
N |
82.7 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-089-02 |
1.00 |
inch |
14.9 |
lb |
47.2 |
lb |
3.50 |
inch |
|
25.4 |
mm |
66.4 |
N |
210 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-089-05 |
2.75 |
inch |
5.5 |
lb |
17.5 |
lb |
3.50 |
inch |
|
69.9 |
mm |
24.6 |
N |
77.7 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-127-01 |
3.75 |
inch |
5.0 |
lb |
15.8 |
lb |
5.00 |
inch |
|
95.3 |
mm |
22.2 |
N |
70.3 |
N |
127.0 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-127-02 |
1.75 |
inch |
13.8 |
lb |
43.7 |
lb |
5.00 |
inch |
|
44.5 |
mm |
61.5 |
N |
194.4 |
N |
127.0 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-127-03 |
1.00 |
inch |
22.4 |
lb |
70.7 |
lb |
5.00 |
inch |
|
25.4 |
mm |
99.5 |
N |
314.5 |
N |
127.0 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-165-01 |
5.25 |
inch |
4.8 |
lb |
15.3 |
lb |
6.50 |
inch |
|
133.4 |
mm |
21.5 |
N |
68.1 |
N |
165.1 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-165-02 |
2.50 |
inch |
13.4 |
lb |
42.3 |
lb |
6.50 |
inch |
|
63.5 |
mm |
59.4 |
N |
187.8 |
N |
165.1 |
mm |
Comparison table
Housing Outside Diameter: 2.000
inch, 50.8 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-051-165-03 |
1.00 |
inch |
26.5 |
lb |
83.8 |
lb |
6.50 |
inch |
|
25.4 |
mm |
117.7 |
N |
372.3 |
N |
165.1 |
mm |
Comparison table
Housing Outside Diameter: 2.750
inch, 69.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-070-038-01 |
0.50 |
inch |
14.5 |
lb |
45.9 |
lb |
1.50 |
inch |
|
12.7 |
mm |
64.6 |
N |
204.4 |
N |
28.6 |
mm |
Comparison table
Housing Outside Diameter: 2.750
inch, 69.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-070-051-01 |
1.00 |
inch |
\
14.6 |
lb |
46.0 |
lb |
2.00 |
inch |
|
25.4 |
mm |
64.7 |
N |
204.3 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 2.750
inch, 69.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-070-064-01 |
1.50 |
inch |
14.4 |
lb |
45.5 |
lb |
2.50 |
inch |
|
38.2 |
mm |
64.0 |
N |
202.0 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 2.750
inch, 69.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-070-064-02 |
0.50 |
inch |
28.7 |
lb |
90.5 |
lb |
2.50 |
inch |
|
12.7 |
mm |
128.0 |
N |
403.0 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 2.750
inch, 69.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-070-089-01 |
2.50 |
inch |
14.1 |
lb |
44.6 |
lb |
3.50 |
inch |
|
63.5 |
mm |
62.8 |
N |
198.3 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 2.750
inch, 69.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-070-089-02 |
1.00 |
inch |
33.9 |
lb |
107.1 |
lb |
3.50 |
inch |
|
25.4 |
mm |
150.7 |
N |
476.3 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 2.750
inch, 69.9 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-070-089-03 |
0.50 |
inch |
41.0 |
lb |
129.6 |
lb |
3.50 |
inch |
|
12.7 |
mm |
182.3 |
N |
576.6 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 3.750
inch, 95.3 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-095-038-01 |
0.50 |
inch |
23.1 |
lb |
73.1 |
lb |
1.50 |
inch |
|
12.7 |
mm |
102.7 |
N |
324.4 |
N |
28.6 |
mm |
Comparison table
Housing Outside Diameter: 3.750
inch, 95.3 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-095-051-01 |
1.00 |
inch |
23.4 |
lb |
70.0 |
lb |
2.0 |
inch |
|
25.4 |
mm |
104.0 |
N |
328.7 |
N |
50.8 |
mm |
Comparison table
Housing Outside Diameter: 3.750
inch, 95.3 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-095-064-01 |
1.50 |
inch |
24.4 |
lb |
77.1 |
lb |
2.50 |
inch |
|
38.2 |
mm |
108.2 |
N |
342.0 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 3.750
inch, 95.3 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-095-064-02 |
0.50 |
inch |
44.9 |
lb |
141.8 |
lb |
2.50 |
inch |
|
12.7 |
mm |
199.1 |
N |
629.2 |
N |
63.5 |
mm |
Comparison table
Housing Outside Diameter: 3.750
inch, 95.3 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-095-089-01 |
2.50 |
inch |
25.0 |
lb |
79.0 |
lb |
3.50 |
inch |
|
63.5 |
mm |
111.2 |
N |
351.3 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 3.750
inch, 95.3 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-095-089-02 |
1.00 |
inch |
58.0 |
lb |
183.1 |
lb |
3.50 |
inch |
|
25.4 |
mm |
257.7 |
N |
814.5 |
N |
88.9 |
mm |
Comparison table
Housing Outside Diameter: 3.750
inch, 95.3 mm |
|
Model # |
Stroke |
|
Continuous Force |
|
Intermittent Force @ 10% Duty Cycle |
|
Housing Length |
|
LVCM-095-089-03 |
0.500 |
inch |
63.9 |
lb |
202.0 |
lb |
3.50 |
inch |
|
12.7 |
mm |
284.1 |
N |
898.4 |
N |
88.9 |
mm |